Date: Thu, 14 Oct 2004 09:51:53 -0500 From: Neven SimicevicTo: carlini@jlab.org Cc: Dave Mack , Mark Pitt , Jim Birchall , Juliette Mammei , Klaus Grimm , Greg Smith , Allena Opper , Tony Forest , Norman Morgan , Mike Finn , David Armstrong , Yongguang Liang , Shelley Page , Richard Jones Subject: Re: Qweak working group: House shaped Cerenkov detector Good Morning Qweak, I did the simulations of V-shaped Cerenkov. It works. I did not know how exactly V-shape will look so I made one based on our recent distributions. It is 16 cm wide, and has a slope of 4 cm over distance of 100 cm. Attached files show the distribution of electrons over the bar, the distribution of photoelectrons for just the bar and for reduction of number of PE as a result of limited acceptance of the phototube. Neven Neven's attachments: 16cm_det_shape.gif 16cm_det_x_position.gif 16cm_det_x_position_red.gif